← Browse

CVE-2026-76325

Medium

Elevated severity or exploit probability.

CVSS base
7.3 HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N
EPSS — probability of exploitation (30 days)
0.3%
16.9th percentile
CISA KEV
Not listed
Weakness / dates
CWE-79
Published 2026-08-19 · modified 2026-08-26

CVSS breakdown

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N

Attack VectorNNetwork
Attack ComplexityLLow
Privileges RequiredLLow
User InteractionRRequired
ScopeUUnchanged
ConfidentialityHHigh
IntegrityHHigh
AvailabilityNNone

Timeline

Description

In Splunk Enterprise versions below 10.4.2, 10.2.6, 10.0.9, and 9.4.14, a user who holds the "power" Splunk role could store a malicious ui-tour knowledge object that matches an auto-tour page name and share the object at the app level. The object can execute arbitrary JavaScript in the browser of another authenticated user who visits a standard Splunk Web page. The JavaScript could expose all relevant data and affect system integrity within the second user permissions. The Cross-Site Scripting (XSS) vulnerability is possible because Splunk Web resolves auto-tour entries from the app namespace and uses untrusted tour content when building the tour image.

Affected

splunk

References

Official: NVD · CVE.org